{"id":3706,"date":"2025-05-24T12:09:17","date_gmt":"2025-05-24T12:09:17","guid":{"rendered":"https:\/\/reactheme.com\/products\/wordpress\/invena-2\/?page_id=3706"},"modified":"2025-11-30T20:05:57","modified_gmt":"2025-11-30T20:05:57","slug":"cables","status":"publish","type":"page","link":"https:\/\/msafiber.com\/index.php\/cables\/","title":{"rendered":"cables"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"3706\" class=\"elementor elementor-3706\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-32ef258 e-flex e-con-boxed e-con e-parent\" data-id=\"32ef258\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-92d34a1 e-flex e-con-boxed e-con e-parent\" data-id=\"92d34a1\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-46b7b6f e-con-full e-flex e-con e-child\" data-id=\"46b7b6f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a77d5af elementor-widget elementor-widget-heading\" data-id=\"a77d5af\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MSA VENUS \nUniversal Polarity \u2013 One System for All Configurations<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a82024 elementor-widget elementor-widget-image\" data-id=\"0a82024\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"640\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/25.png\" class=\"attachment-large size-large wp-image-10969\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/25.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/25-300x300.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/25-150x150.png 150w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/25-768x768.png 768w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/25-87x87.png 87w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf47cb3 elementor-widget elementor-widget-text-editor\" data-id=\"cf47cb3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Optical Cables:<\/strong>\u2028 Type B\u2028<\/p><p><strong>\u2028\u2028Cassettes and \u2018hydras\u2019:<\/strong> Universal<\/p><p><strong>Patch-cords:<\/strong> \u2028Standard A-B \/ B-A<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d8bd76 elementor-widget elementor-widget-heading\" data-id=\"7d8bd76\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">VENUS and VENUS 8 MTP trunk cables<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f7202b elementor-widget elementor-widget-image\" data-id=\"8f7202b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"327\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab2.png\" class=\"attachment-large size-large wp-image-11200\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab2.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab2-300x153.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab2-768x393.png 768w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2517ef5 elementor-widget elementor-widget-text-editor\" data-id=\"2517ef5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Bend-resistant VENUS and VENUS 8 MTP trunk cables are designed to meet the demands of high-density connections and high performance. These trunk cables come with cable holders for secure fixation within VENUS racks and panels.<\/p><ul role=\"list\"><li>From 8 to 144 fibers in a single MTP cable<\/li><li>Installation sleeves for secure mounting<\/li><li>LSZH jacket (low smoke, zero halogen)<\/li><li>Bend-resistant fiber types: MM OM3, OM4, OM5 (IEC 60793-2-10, type A1a.2, A1a.3) and SM (ITU-T G.657.A2)<\/li><li>Compliant with Telcordia GR-1435-CORE, IEC 61754-7, TIA 568-C.3, IEC 60793-1, IEEE 802.3ba, IEC 11801, TIA-492.AAAC, TIA-492.AAAD, and TIA-942-A standards<\/li><li>RoHS directive compliant (restriction of hazardous substances)<\/li><li>Customizable configurations tailored to customer requirements<\/li><li>Simple and cost-effective upgrade path 10G to 1600G without replacing trunk cables<\/li><li>High performance while saving space in cable pathways<\/li><li>Ideal for installations with high-density connection and operational readiness demands, supporting Disaster Recovery Plans (DRP), Business Continuity Planning (BCP), and central data center hubs<\/li><li>Insertion loss levels exceed the strict criteria of the TIA 942-A standard<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1548901 elementor-widget elementor-widget-image\" data-id=\"1548901\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"837\" height=\"382\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/image-34.png\" class=\"attachment-full size-full wp-image-11602\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/image-34.png 837w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/image-34-300x137.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/image-34-768x351.png 768w\" sizes=\"(max-width: 837px) 100vw, 837px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3030c2 elementor-widget elementor-widget-heading\" data-id=\"c3030c2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MTP-LC splitter cables (fanout \/ breakout cables)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90ad1de elementor-widget elementor-widget-image\" data-id=\"90ad1de\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"640\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab3.png\" class=\"attachment-large size-large wp-image-11202\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab3.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab3-300x300.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab3-150x150.png 150w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab3-768x768.png 768w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab3-87x87.png 87w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f17d0b elementor-widget elementor-widget-text-editor\" data-id=\"5f17d0b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>MTP-LC<\/strong> fanout cable assemblies combine <strong>MTP<\/strong> connectors\u2014designed for connection to VENUS cassettes\u2014with LC UNIBOOT duplex connectors for direct connection to active equipment. These assemblies provide additional cabling options for data center infrastructure.<\/p><ul role=\"list\"><li>From 8 to 48 fibers in a single MTP cable<\/li><li>LSZH jacket (Low Smoke Zero Halogen)<\/li><li>Bend-resistant fiber types: MM OM3, OM4, OM5 (IEC 60793-2-10, type A1a.2, A1a.3) and SM (ITU-T G.657.A2)<\/li><li>Compliant with: Telcordia GR-1435-CORE, IEC 61754-7, IEC 60793-1, IEC 11801, TIA 568-C.3, TIA-492.AAAC, TIA-492.AAAD, TIA-942-A, IEEE 802.3ba<\/li><li>RoHS compliant (Restriction of Hazardous Substances)<\/li><li>Compatible with all VENUS optical panels<\/li><li>Configurable to meet specific customer requirements<\/li><li>High performance with efficient space usage in cable pathways<\/li><li>Ideal for deployments with strict density and operational readiness requirements, including Disaster Recovery Plans (DRP), Business Continuity Planning (BCP), and core data center nodes<\/li><li>Insertion loss meets stricter criteria than those defined by the TIA 942-A standard<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2af9523 elementor-widget elementor-widget-heading\" data-id=\"2af9523\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Fiber Optics Cords and Cables<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e76569 elementor-widget elementor-widget-image\" data-id=\"4e76569\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"640\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab4.png\" class=\"attachment-large size-large wp-image-11203\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab4.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab4-300x300.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab4-150x150.png 150w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab4-768x768.png 768w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab4-87x87.png 87w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5e2bac elementor-widget elementor-widget-text-editor\" data-id=\"a5e2bac\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>VENUS and VENUS 8 optic cords are designed to deliver maximum performance in environments with minimal installation space<\/p><ul role=\"list\"><li>Contains 12\/8 fibers in a slim, flexible 2.0 mm LSZH jacket (Low Smoke Zero Halogen)<\/li><li>Bend-resistant fiber types: MM OM3, OM4, OM5 (IEC 60793-2-10, type A1a.2, A1a.3) and SM (ITU-T G.657.A2)<\/li><li>Compliant with Telcordia GR-1435-CORE, IEC 61754-7, TIA 568-C.3, IEC 60793-1, IEEE 802.3ba, IEC 11801, TIA-492.AAAC, TIA-492.AAAD, and TIA-942-A standards<\/li><li>RoHS compliant (Restriction of Hazardous Substances)<\/li><li>Supports quick moves, adds, and changes, with easy maintenance of structured cabling systems<\/li><li>Designed for high-density and high-availability installations, including core data center nodes, with support for Disaster Recovery Planning (DRP) and Business Continuity Planning (BCP)<\/li><li>Factory-terminated LC connectors for high performance, compliant with TIA\/EIA 604-10 (LC FOCIS 10)<\/li><li>Factory-terminated MTP\u00ae Elite connectors exceed TIA\/EIA 604-5 (MPO FOCIS 5) performance standards<\/li><li>MTP\u00ae PRO connectors enable fast polarity and pin reconfiguration in the field\u2014no need to disassemble the connector housing<\/li><li>MTP\u00ae PRO features a push-pull boot for easy connect\/disconnect access<\/li><li>Field reconfiguration requires the MTP\u00ae PRO Field Tool (Part No. 18963)<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20fa142 elementor-widget elementor-widget-heading\" data-id=\"20fa142\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">VENUS LC duplex patch cords<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7de3604 elementor-widget elementor-widget-image\" data-id=\"7de3604\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"640\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/29-1.png\" class=\"attachment-large size-large wp-image-11124\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/29-1.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/29-1-300x300.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/29-1-150x150.png 150w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/29-1-768x768.png 768w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/29-1-87x87.png 87w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c413872 elementor-widget elementor-widget-text-editor\" data-id=\"c413872\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>VENUS LC duplex patch cords are designed to deliver maximum performance in environments with limited installation space<\/p><ul role=\"list\"><li>Universal CORE optical LC duplex patch cord with single boot (Uniboot design)<\/li><li>Dual-fiber 2.0 mm unified jacket saves up to 50% cable volume<\/li><li>LSZH jacket (Low Smoke Zero Halogen)<\/li><li>Bend-resistant fiber types: MM OM3, OM4, OM5 (IEC 60793-2-10, type A1a.2, A1a.3) and SM (ITU-T G.657.A2)<\/li><li>Standards compliance: TIA-604-10 (LC FOCIS 10), IEC 61754-20, TIA 568-C.3, IEC 60793-1, IEC 61755-3, IEC 11801 (OS2, OM3, OM4), TIA-492.AAAC, TIA-492.AAAD, TIA 942-A, IEEE 802.3ae (10 Gb\/s Ethernet)<\/li><li>RoHS compliant (Restriction of Hazardous Substances)<\/li><li>Tool-free polarity reversal<\/li><li>Supports fast moves, adds, and changes with easy maintenance of structured cabling systems<\/li><li>Ideal for high-density, high-availability environments\u2014including core data center nodes\u2014with consideration for Disaster Recovery Planning (DRP) and Business Continuity Planning (BCP)<\/li><li>Factory-terminated connectors ensure high performance in accordance with TIA\/EIA 604-10 (LC FOCIS 10)<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd53d4e elementor-widget elementor-widget-heading\" data-id=\"cd53d4e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Polarity Selection Guidelines<br>for MTP\/MPO Multi-Fiber Links<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-695978d elementor-widget elementor-widget-image\" data-id=\"695978d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"449\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab5.png\" class=\"attachment-full size-full wp-image-11204\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab5.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab5-300x168.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab5-768x431.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e98104 elementor-widget elementor-widget-text-editor\" data-id=\"2e98104\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The recommended method allows the creation of multi-fiber links of any complexity using standardized components and a unified strategy. These polarity guidelines apply to 12-fiber and 8-fiber MTP\/MPO links, suitable for most applications. If your situation differs from these recommendations, please contact us \u2014 we\u2019ll be happy to assist.<\/p><p><strong>12-Fiber Links<\/strong><\/p><p><strong>1. All MTP\/MPO<\/strong> trunk cables and patch cords must use Polarity B.\u2028<\/p><ul><li>All MTP\/MPO trunk cables must be female\u2013female.\u2028<\/li><li>All MTP\/MPO patch cords must be male\u2013female.\u2028 \u00a0\u00a0\u00a0\u00a0\u2014 MTP PRO male\u2013female patch cords are recommended.\u2028<\/li><li>All MTP\/MPO through adapters in cassettes must be Key-Up to Key-Down.<\/li><\/ul><p><strong>2. When converting an MTP\/MPO<\/strong> link to a duplex environment, use Type U universal polarity cassettes on both ends.\u2028<\/p><ul><li>The wiring scheme for Type U cassettes is shown in the diagram.\u2028<\/li><li>Cassette MTP\/MPO ports must be male.\u2028<\/li><li>Use standard LC A-B duplex patch cords for connectivity.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6c418b elementor-widget elementor-widget-heading\" data-id=\"a6c418b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Polarity Selection Guidelines<br>for MTP\/MPO Multi-Fiber Links<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e57c8e5 elementor-widget elementor-widget-image\" data-id=\"e57c8e5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"182\" src=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab6.png\" class=\"attachment-full size-full wp-image-11205\" alt=\"\" srcset=\"https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab6.png 800w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab6-300x68.png 300w, https:\/\/msafiber.com\/wp-content\/uploads\/2025\/11\/cab6-768x175.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa06374 elementor-widget elementor-widget-text-editor\" data-id=\"fa06374\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>8-Fiber Links<\/strong><\/p><p><strong>1. All MTP\/MPO<\/strong> trunk cables and patch cords must use Polarity B.\u2028<\/p><ul><li>All MTP\/MPO trunk cables must be male\u2013male.\u2028<\/li><li>All MTP\/MPO patch cords must be female\u2013female.\u2028 \u00a0\u00a0\u00a0\u00a0\u2014 MTP PRO female\u2013female patch cords are recommended.\u2028<\/li><li>All MTP\/MPO through adapters in cassettes must be Key-Up to Key-Down.<\/li><\/ul><p><strong>2. When converting an MTP\/MPO<\/strong> link to a duplex environment, use Type U universal polarity cassettes on both ends.\u2028<\/p><ul><li>The wiring scheme for Type U cassettes is shown in the diagram.\u2028<\/li><li>Cassette MTP\/MPO ports must be female.\u2028<\/li><li>Use standard LC A-B duplex patch cords for connectivity.<\/li><\/ul><p><strong>Singlemode Links<\/strong><\/p><p>All MTP\/MPO connectors for singlemode fibers are APC polished.\u2028 Therefore, Key-Up to Key-Up adapters must not be used in singlemode systems.\u2028 These types of adapters are not included in our recommendations.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>MSA VENUS Universal Polarity \u2013 One System for All Configurations Optical Cables:\u2028 Type B\u2028 \u2028\u2028Cassettes and \u2018hydras\u2019: Universal Patch-cords: \u2028Standard A-B \/ B-A VENUS and VENUS 8 MTP trunk cables Bend-resistant VENUS and VENUS 8 MTP trunk cables are designed to meet the demands of high-density connections and high performance. These trunk cables come with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-3706","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/pages\/3706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/comments?post=3706"}],"version-history":[{"count":53,"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/pages\/3706\/revisions"}],"predecessor-version":[{"id":11605,"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/pages\/3706\/revisions\/11605"}],"wp:attachment":[{"href":"https:\/\/msafiber.com\/index.php\/wp-json\/wp\/v2\/media?parent=3706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}